Range: Preventa XCS

Safety Switches

XCSDM379110

XCSDM379110 Product picture
Range: Preventa XCS

Safety Switches

XCSDM379110

coded magnetic system XCSDM3 - SIL 2 - 2 PNP outputs - cable 10m

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    Preventa Safety detection
    product or component type
    Coded magnetic system
    component name
    XCSDM3
    design
    Rectangular
    size
    100 x 34 x 32 mm
    contacts type and composition
    1 NO + 1 NO
    material
    Plastic
    electrical connection
    Pre-cabled
    cable composition
    6 x 0.25 mm²
    cable length
    10 m
    ohmic cable resistance
    900 mOhm
    local signalling
    1 LED (green, orange and red)
    approach directions
    9 directions
    [Ue] rated operational voltage
    24 V DC (- 20...10 %)
    [Ui] rated insulation voltage
    36 V DC
    Complementary
    cable outer diameter
    6.1 mm
    type of output stage
    Solid-state, PNP
    safety outputs
    2 outputs 1.5 A, 24 V, DC
    [Sa] assured operating distance
    10 mm
    [Sar] assured tripping distance
    20 mm
    minimum actuation speed
    0.01 m/s
    [Uimp] rated impulse withstand voltage
    2.5 kV conforming to EN/IEC 60947-5-1
    protection type
    Overload and short-circuit protection
    switching frequency
    3 Hz
    time delay
    100 ms (activation)
    discordance time
    2 s
    [HFT] Hardware Fault Tolerance
    1
    tightening torque
    < 1.8 N.m
    installed device
    32 maximum with 2 m long cable
    marking
    CE
    safety level
    Can reach category 3 (correctly wired) conforming to EN/ISO 13849-1
    Can reach PL = d (correctly wired) conforming to EN/ISO 13849-1
    Can reach SIL 2 (correctly wired) conforming to EN/IEC 61508
    safety reliability data
    HFT = 1
    MTTFd = 182 years
    PFD = 1.15E-5
    PFH = 3.94E-9
    SF = 92.5 %
    enclosure material
    Thermoplastic PBT
    cable material
    PVC
    depth
    32 mm
    height
    100 mm
    width
    34 mm
    product weight
    0.745 kg
    Environment
    standards
    EN 1088
    EN 13849-1
    EN/IEC 60947-5-1
    EN/IEC 60947-5-2
    EN/IEC 60947-5-3
    EN/IEC 62061
    IEC 61508
    ISO 14119
    product certifications
    CSA
    TÜV
    UL
    ambient air temperature for operation
    -25...70 °C
    ambient air temperature for storage
    -40...85 °C
    vibration resistance
    10 gn (f = 10...500 Hz) conforming to IEC 60068-2-6
    shock resistance
    30 gn for 11 ms conforming to IEC 60068-2-27
    sensitivity to magnetic fields
    <= 0.5 mT
    electrical shock protection class
    Class III conforming to EN/IEC 61140
    IP degree of protection
    IP66 conforming to IEC 60529
    IP67 conforming to IEC 60529
    IP69K conforming to DIN 40050
    Offer Sustainability
    RoHS (date code: YYWW)
    REACh
    Contractual warranty
    Warranty period
    18 months
  • Documents & Downloads

    Language
    • English
    Instruction sheet
    Date
    Size
    Add to My Documents
    Date 18/05/17
    Size 684.7 KB
    Declaration of conformity
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Nos conseillers sont disponibles pour répondre à vos questions de 8h00 à 18h00 du lundi au vendredi toute l'année.