Australia

Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

XACS411 Product picture

View all Harmony XAC

Harmony XAC - XACS411

Pendant control stations for customer assembly

XACS411 Product picture
View all Harmony XAC
Harmony XAC - XACS411
Pendant control stations for customer assembly

spring return contact block - 1 NO - front mounting, 30 or 40 mm centres

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    Harmony XAC
    product or component type
    Contact block
    component name
    XACS
    electrical circuit type
    Control circuit
    contact block type
    Single
    type of operator
    Spring return
    product compatibility
    XACA
    ZA2B... head
    mechanical interlocking
    Without mechanical interlock
    contacts type and composition
    1 NO
    mounting of block
    Front mounting
    contact operation
    Slow-break
    Complementary
    connections - terminals
    Screw clamp terminals, connection capacity: 1 x 2.5 mm² with or without cable end
    Screw clamp terminals, connection capacity: 2 x 1.5 mm² with or without cable end
    horizontal fixing centres
    40 mm
    vertical fixing centres
    30 mm
    mechanical durability
    1000000 cycles
    contact code designation
    A300 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A
    Q300 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
    [Ithe] conventional enclosed thermal current
    10 A
    [Ui] rated insulation voltage
    500 V (degree of pollution: 3) conforming to IEC 60947-1
    [Uimp] rated impulse withstand voltage
    6 kV conforming to IEC 60947-1
    resistance across terminals
    <= 25 MOhm
    short-circuit protection
    10 A fuse protection by cartridge fuse type gG
    rated operational power in W
    42 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
    45 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
    60 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
    rated operational power in VA
    140 VA AC-15 for 1000000 cycles, operating rate = 60 cyc/mn at 24 V 50/60 Hz, load factor = 0.5 (inductive load)
    385 VA AC-15 for 1000000 cycles, operating rate = 60 cyc/mn at 48 V 50/60 Hz, load factor = 0.5 (inductive load)
    455 VA AC-15 for 1000000 cycles, operating rate = 60 cyc/mn at 230 V 50/60 Hz, load factor = 0.5 (inductive load)
    525 VA AC-15 for 1000000 cycles, operating rate = 60 cyc/mn at 127 V 50/60 Hz, load factor = 0.5 (inductive load)
    terminals description ISO n°1
    (13-14)NO
    terminal identifier
    (11-12)NC
    (13-14)NO
    product weight
    0.07 kg
    Environment
    standards
    EN 60947-5-1
    IEC 60947-5-1
    CSA C22.2 No 14
    ambient air temperature for operation
    -25...70 °C
    ambient air temperature for storage
    -40...70 °C
    vibration resistance
    15 gn (f = 10...500 Hz) conforming to IEC 60068-2-6
    shock resistance
    100 gn conforming to IEC 60068-2-27
    Contractual warranty
    Warranty period
    18 months
  • Documents & Downloads

    Language
    • English
    Certificate
    Date
    Size
    Add to My Documents
    Date 26/10/18
    Size 1.8 MB
    Date 14/11/18
    Size 897 KB
    Declaration of conformity
    Date
    Size
    Add to My Documents
    Date 14/11/18
    Size 433.9 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions



  • Mounting and Clearance

    Mounting



  • Performance Curves

    Rated Operational Power
    AC Supply 50/60 Hz

    Operating rate: 3600 operating cycles/hour. Load factor: 0.5.

    Power broken in VA for 1 million operating cycles, AC-15 utilization category

    Voltage

    V

    24

    48

    127

    230

    Inductive circuit

    W

    140

    385

    525

    455

    DC Supply

    Operating rate: 3600 operating cycles/hour. Load factor: 0.5.

    Power broken in W for 1 million operating cycles, DC-13 utilization category

    Voltage

    V

    24

    48

    120

    Inductive circuit

    W

    60

    45

    42


Nos conseillers sont disponibles pour répondre à vos questions de 8h00 à 18h00 du lundi au vendredi toute l'année.