Australia

Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

XACA4714 Product picture

View all Harmony XAC

Harmony XAC - XACA4714

Complete pendant control stations

XACA4714 Product picture
View all Harmony XAC
Harmony XAC - XACA4714
Complete pendant control stations

pendant control station XAC-A - 4 pushbuttons 1 Emergency stop

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    Harmony XAC
    product or component type
    Pendant control station
    device short name
    XACA
    Complementary
    control station type
    Double insulated
    enclosure material
    Polypropylene
    electrical circuit type
    Control circuit
    enclosure type
    Complete ready for use
    control station application
    Control of single speed hoist motor
    control station composition
    4 push-buttons + 1 emergency stop
    control button type
    First push-button 1 NO raise, slow
    Second push-button 1 NO lower, slow
    Fourth push-button 1 NO left, slow
    Third push-button 1 NO right, slow
    Emergency stop push-button Ø 40 mm 1 NC trigger action
    product compatibility
    ZB2BE101 for each direction
    ZB2BE102 for emergency stop
    mechanical interlocking
    With mechanical interlocking between pairs
    control station colour
    Yellow
    connections - terminals
    Screw clamp terminals 1 x 0.5...2 x 1.5 mm² with cable end
    Screw clamp terminals 1 x 0.5...1 x 2.5 mm² without cable end
    standards
    EN/IEC 60204-32
    EN/IEC 60947-5-1
    EN/IEC 60947-5-5
    EN/ISO 13850: 2006
    UL 508
    CSA C22.2 No 14
    product certifications
    CCC
    GOST
    protective treatment
    TH
    ambient air temperature for operation
    -25...70 °C
    ambient air temperature for storage
    -40...70 °C
    vibration resistance
    15 gn 10...500 Hz IEC 60068-2-6
    shock resistance
    100 gn IEC 60068-2-27
    overvoltage category
    Class II IEC 61140
    IP degree of protection
    IP65 IEC 60529
    IK degree of protection
    IK08 EN 50102
    mechanical durability
    1000000 cycles
    cable entry
    Rubber sleeve with stepped entry 8...26 mm
    contact code designation
    A600 AC-15 240 V 3 A IEC 60947-5-1 appendix A
    A600 AC-15 600 V 1.2 A IEC 60947-5-1 appendix A
    Q600 DC-13 250 V 0.27 A IEC 60947-5-1 appendix A
    Q600 DC-13 600 V 0.1 A IEC 60947-5-1 appendix A
    [Ithe] conventional enclosed thermal current
    10 A
    [Ui] rated insulation voltage
    600 V 3
    [Uimp] rated impulse withstand voltage
    6 kV IEC 60947-1
    contact operation
    Slow-break
    resistance across terminals
    <= 25 MOhm
    operating force
    10 N push-button
    8 N emergency stop
    short-circuit protection
    10 A fuse protection cartridge gG
    rated operational power in W
    40 W DC-13 1000000 cycles 60 cyc/mn 120 V 0.5 inductive IEC 60947-5-1 appendix C
    48 W DC-13 1000000 cycles 60 cyc/mn 48 V 0.5 inductive IEC 60947-5-1 appendix C
    65 W DC-13 1000000 cycles 60 cyc/mn 24 V 0.5 inductive IEC 60947-5-1 appendix C
    terminals description ISO n°1
    (13-14)NO
    terminals description ISO n°2
    (11-12)NC
    terminal identifier
    (11-12)NC
    (13-14)NO
    product weight
    0.8 kg
    Contractual warranty
    Warranty period
    18 months
  • Documents & Downloads

    Language
    • English
    Instruction sheet
    Date
    Size
    Add to My Documents
    Date 12/04/18
    Size 2.6 MB
    Certificate
    Date
    Size
    Add to My Documents
    Date 29/10/18
    Size 102 KB
    Date 29/10/18
    Size 88.7 KB
    Date 26/10/18
    Size 2.2 MB
    Date 14/11/18
    Size 897 KB
    Declaration of conformity
    Date
    Size
    Add to My Documents
    Date 14/11/18
    Size 415 KB
    Product environmental
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions

    Below drawing shows a product with 6 cut-outs. Select the number of cut-outs according to the product characteristics in order to get b, b1 and c dimensions.


    (1)
    For 2 and 3-way XAC A stations.
    (2)
    For 4 to 8-way XAC A stations.
    (3)
    With trigger action Emergency stop head operator
    (4)
    Internal ø

    Dimensions in mm

    Number of cut-outs

    2

    3

    4

    5

    6

    8

    12

    b

    314

    314

    440

    440

    500

    560

    680

    b1

    190

    190

    250

    250

    310

    370

    490

    c

    80

    80

    80

    80

    80

    80

    92

    Dimensions in in.

    Number of cut-outs

    2

    3

    4

    5

    6

    8

    12

    b

    12.36

    12.36

    17.32

    17.32

    19.68

    22.05

    26.77

    b1

    7.48

    7.48

    9.84

    9.84

    12.20

    14.57

    19.29

    c

    3.15

    3.15

    3.15

    3.15

    3.15

    3.15

    3.62


  • Connections and Schema

    Control of Single-Speed Reversing Motor

    With ZBE2BE101 + ZB2BE102 contacts blocks, to be ordered separately



  • Performance Curves

    Rated Operational Power
    AC Supply 50/60 Hz Inductive Circuit

    Operating rate: 3600 operating cycles/hour. Load factor: 0.5.

    Millions of operating cycles, AC-15 utilization category


    Ithe
    Thermal current
    (A)
    Current

    DC Supply

    Operating rate: 3600 operating cycles/hour. Load factor: 0.5.

    Power broken in W for 1 million operating cycles, DC-13 utilization category

    Voltage

    V

    24

    48

    120

    Inductive circuit

    W

    65

    48

    40