Australia

Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

pendant control station XAC-A - 2 pushbuttons

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    Harmony XAC
    product or component type
    Pendant control station
    device short name
    XACA
    Complementary
    control station type
    Double insulated
    enclosure material
    Polypropylene
    electrical circuit type
    Control circuit
    enclosure type
    Complete ready for use
    control station application
    Control of 2-speed hoist motor
    control station composition
    2 push-buttons
    control button type
    First push-button 1 NC + 2 NO raise, slow-fast
    Second push-button 1 NC + 2 NO lower, slow-fast
    product compatibility
    XENG1191 for each direction
    mechanical interlocking
    With mechanical interlocking
    control station colour
    Yellow
    connections - terminals
    Screw clamp terminals 1 x 0.5...2 x 1.5 mm² with cable end
    Screw clamp terminals 1 x 0.5...1 x 2.5 mm² without cable end
    standards
    EN/IEC 60204-32
    EN/IEC 60947-5-1
    UL 508
    CSA C22.2 No 14
    product certifications
    CCC
    GOST
    protective treatment
    TH
    ambient air temperature for operation
    -25...70 °C
    ambient air temperature for storage
    -40...70 °C
    vibration resistance
    15 gn 10...500 Hz IEC 60068-2-6
    shock resistance
    100 gn IEC 60068-2-27
    overvoltage category
    Class II IEC 61140
    IP degree of protection
    IP65 IEC 60529
    IK degree of protection
    IK08 EN 50102
    mechanical durability
    1000000 cycles
    cable entry
    Rubber sleeve with stepped entry 8...26 mm
    contact code designation
    A600 AC-15 240 V 3 A IEC 60947-5-1 appendix A
    A600 AC-15 600 V 1.2 A IEC 60947-5-1 appendix A
    Q600 DC-13 250 V 0.27 A IEC 60947-5-1 appendix A
    Q600 DC-13 600 V 0.1 A IEC 60947-5-1 appendix A
    [Ithe] conventional enclosed thermal current
    10 A
    [Ui] rated insulation voltage
    600 V 3
    [Uimp] rated impulse withstand voltage
    6 kV IEC 60947-1
    contact operation
    Slow-break
    Staggered
    resistance across terminals
    <= 25 MOhm
    operating force
    18 N push-button
    short-circuit protection
    10 A fuse protection cartridge gG
    rated operational power in W
    40 W DC-13 1000000 cycles 60 cyc/mn 120 V 0.5 inductive IEC 60947-5-1 appendix C
    48 W DC-13 1000000 cycles 60 cyc/mn 48 V 0.5 inductive IEC 60947-5-1 appendix C
    65 W DC-13 1000000 cycles 60 cyc/mn 24 V 0.5 inductive IEC 60947-5-1 appendix C
    terminals description ISO n°1
    (13-14)NO
    (21-22)NC
    (33-34)NO_CL
    terminal identifier
    (11-12)NC
    (13-14)NO
    product weight
    0.525 kg
    Contractual warranty
    Warranty period
    18 months
  • Documents & Downloads

    Language
    • English
    • Kazakh
    • Russian
    • French
    Catalogue
    Date
    Size
    Add to My Documents
    Harmony XAC pendant control stations catalog (Version 1.0)
    Instruction sheet
    Date
    Size
    Add to My Documents
    XAC A... Pendant control stations (Version 08)
    CAD
    Date
    Size
    Add to My Documents
    Certificate
    Date
    Size
    Add to My Documents
    XAC, XAL, XAPS, XAW Control Stations (Version 1.0)
    XACA Pendant control station (Version 1.0)
    Date 26/10/18
    Size 2.2 MB
    XACA Pendant control station and XALD, XALK Control stations (Version 1.0)
    XACA Pendant control station (Version 1.0)
    Date 29/10/18
    Size 88.7 KB
    XACA Pendant control station (Version 1.0)
    Date 29/10/18
    Size 102 KB
    Declaration of conformity
    Date
    Size
    Add to My Documents
    XACA... Pendant control station 2 to 12 buttons (Version 1.0)
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    XACA empty pendant control station enclosures, Product Environmental Profile (Version 2.0)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions

    Below drawing shows a product with 6 cut-outs. Select the number of cut-outs according to the product characteristics in order to get b, b1 and c dimensions.


    (1)
    For 2 and 3-way XAC A stations.
    (2)
    For 4 to 8-way XAC A stations.
    (3)
    With trigger action Emergency stop head operator
    (4)
    Internal ø

    Dimensions in mm

    Number of cut-outs

    2

    3

    4

    5

    6

    8

    12

    b

    314

    314

    440

    440

    500

    560

    680

    b1

    190

    190

    250

    250

    310

    370

    490

    c

    80

    80

    80

    80

    80

    80

    92

    Dimensions in in.

    Number of cut-outs

    2

    3

    4

    5

    6

    8

    12

    b

    12.36

    12.36

    17.32

    17.32

    19.68

    22.05

    26.77

    b1

    7.48

    7.48

    9.84

    9.84

    12.20

    14.57

    19.29

    c

    3.15

    3.15

    3.15

    3.15

    3.15

    3.15

    3.62


  • Connections and Schema

    Control of 2-Speed Reversing Motor

    With two XENG1191 contact blocks, to be ordered separately


    KM
    High speed contactor


  • Performance Curves

    Rated Operational Power
    AC Supply 50/60 Hz Inductive Circuit

    Operating rate: 3600 operating cycles/hour. Load factor: 0.5.

    Millions of operating cycles, AC-15 utilization category


    Ithe
    Thermal current
    (A)
    Current

    DC Supply

    Operating rate: 3600 operating cycles/hour. Load factor: 0.5.

    Power broken in W for 1 million operating cycles, DC-13 utilization category

    Voltage

    V

    24

    48

    120

    Inductive circuit

    W

    65

    48

    40