Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

    METSEPM5350 Product picture

    Range: PM5350

    Basic multi-function metering

    METSEPM5350

    METSEPM5350 Product picture
    Range: PM5350

    Basic multi-function metering

    METSEPM5350

    PM5350 power monitor

    Show more characteristics >
    Add to My Favourites Remove from My Favourites

    • Main
      range
      PowerLogic
      product name
      PowerLogic PM5350
      device short name
      PM5350
      product or component type
      Power meter
      Complementary
      power quality analysis
      Total demand distortion
      Total harmonic distortion
      device application
      Power monitoring
      type of measurement
      Phase angle
      Energy
      Voltage
      Current
      Frequency
      Active power
      Power factor
      Reactive power
      Apparent power
      [Us] rated supply voltage
      85...265 V AC (45...65 Hz)
      100...300 V DC
      network frequency
      50 Hz
      60 Hz
      [In] rated current
      1 A
      5 A
      poles description
      1P + N
      3P
      3P + N
      power consumption in VA
      <= 9.6 VA
      display type
      Backlit LCD
      display resolution
      6 lines
      sampling rate
      32 samples/cycle
      measurement current
      0...5 A
      0...1 A
      analogue input type
      Current 0.05...9 A (impedance <= 0.3 Ohm)
      measurement voltage
      20...690 V AC phase to phase
      20...400 V AC phase to neutral
      frequency measurement range
      45...70 Hz
      number of inputs
      4 digital
      measurement accuracy
      0.3 % current
      0.3 % voltage
      0.05 % frequency
      0.005 % power factor
      accuracy class
      Class 0.5S (active energy according to IEC 62053-22)
      Class 0.5 (power according to IEC 61557-12)
      Class 0.5 (active energy according to IEC 61557-12)
      Class 3 (reactive energy according to IEC 62053-23)
      Class 2 (reactive energy according to IEC 61557-12)
      number of outputs
      2 relay
      information displayed
      Tariff 4
      communication port protocol
      JBUS
      Modbus RTU and ASCII : 9.6, 19.2 and 38.4 kbauds,
      communication port support
      RS485 terminal block
      data recording
      Alarms
      Min/max of instantaneous values
      connections - terminals
      Voltage circuit: 4 screw terminal block
      Control circuit: 2 screw terminal block
      Current transformer: 6 screw terminal block
      Input/output circuit: 6 screw terminal block
      Relay output: 4 screw terminal block
      Ethernet network: RJ45 connector
      mounting mode
      Flush-mounted
      type of installation
      Indoor installation
      standards
      IEC 61010-1
      product certifications
      CULus
      CE
      width
      96 mm
      depth
      44 mm
      height
      96 mm
      product weight
      0.25 kg
      Environment
      electromagnetic compatibility
      ● susceptibility to electromagnetic fields, conforming to IEC 61000-4-3
      ● electrical fast transient/burst immunity test, conforming to IEC 61000-4-4
      ● 1.2/50 µs shock waves immunity test, conforming to IEC 61000-4-5
      ● conducted RF disturbances, conforming to IEC 61000-4-6
      ● immunity to impulse waves, conforming to IEC 61000-4-12
      ● limits for harmonic current emissions, conforming to IEC 61000-3-2
      ● limitation of voltage changes, voltage fluctuations and flicker in low-voltage, conforming to IEC 61000-3-3
      ● electrostatic discharge, conforming to IEC 61000-4-2
      ● conducted and radiated emissions class class A, conforming to EN 55011
      overvoltage category
      III
      IP degree of protection
      IP30 (back) conforming to IEC 60529
      IP51 (front face) conforming to IEC 60529
      relative humidity
      0...95 % 50 °C
      pollution degree
      2
      ambient air temperature for operation
      -40...85 °C
      ambient air temperature for storage
      -25...70 °C
      operating altitude
      0...3000 m
      Offer Sustainability
      Sustainable offer status
      Green Premium product
      RoHS (date code: YYWW)
      Compliant  - since  1104  -  Schneider Electric declaration of conformity Schneider Electric declaration of conformity
      REACh
      Product environmental profile
      Product end of life instructions
      Available
      Contractual warranty
      Warranty period
      18 months
    • Documents & Downloads

      Language
      • English
      Catalogue
      Date
      Size
      Add to My Documents
      Date 13/04/18
      Size 6.2 MB
      Date 13/04/18
      Size 1.1 MB
      Instruction sheet
      Date
      Size
      Add to My Documents
      Date 13/03/18
      Size 2.2 MB
      Technical leaflet
      Date
      Size
      Add to My Documents
      Date 7/02/18
      Size 1.7 MB
      Date 7/02/18
      Size 1.1 MB
      Declaration of conformity
      Date
      Size
      Add to My Documents
      Date 10/05/16
      Size 641.5 KB
      Product environmental
      Date
      Size
      Add to My Documents
      Date 21/02/12
      Size 421.3 KB
    • Technical FAQs

      No results found.
      Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
    Nos conseillers sont disponibles pour répondre à vos questions de 8h00 à 18h00 du lundi au vendredi toute l'année.