Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

    LV426109 Product picture

    Range: Compact NSXm

    Circuit breakers

    LV426109

    LV426109 Product picture
    Range: Compact NSXm

    Circuit breakers

    LV426109

    circuit breaker Compact NSXm 160A 3P 16kA at 380/415V(IEC) EverLink lug

    Show more characteristics >
    Add to My Favourites Remove from My Favourites

    • Main
      range
      Compact
      product name
      Compact NSXm
      device short name
      NSXm 160E
      product or component type
      Circuit breaker
      device application
      Distribution
      Protection
      Complementary
      [In] rated current
      160 A
      poles description
      3P 3d
      control type
      Toggle
      mounting mode
      By screws for plate
      Clip-on for DIN rail
      network type
      AC
      network frequency
      50/60 Hz
      breaking capacity code
      E
      breaking capacity
      25 kA at 220...240 V AC 50/60 Hz according to IEC 60947-2
      16 kA at 380...415 V AC 50/60 Hz according to IEC 60947-2
      10 kA at 440 V AC 50/60 Hz according to IEC 60947-2
      [Ue] rated operational voltage
      690 V AC 50/60 Hz according to IEC 60947-2
      [Ics] rated service breaking capacity
      25 kA at 220...240 V AC 50/60 Hz according to IEC 60947-2
      16 kA at 380...415 V AC 50/60 Hz according to IEC 60947-2
      10 kA at 440 V AC 50/60 Hz according to IEC 60947-2
      [Uimp] rated impulse withstand voltage
      8 kV according to IEC 60947-2
      [Ui] rated insulation voltage
      800 V according to IEC 60947-2
      trip unit technology
      Thermal-magnetic
      trip unit name
      TM-D
      trip unit protection functions
      LI
      trip unit rating
      160 A at 40 °C
      protection type
      Overload protection (thermal)
      Short-circuit protection (magnetic)
      long time pick-up adjustment range
      0.7...1 x In
      short-time pick-up adjustment type Isd
      Fixed
      short-time delay adjustment type
      Fixed
      magnetic hold current
      1000 A
      magnetic tripping current
      1500 A
      suitability for isolation
      Yes according to IEC 60947-2
      utilisation category
      Category A
      9 mm pitches
      9 module
      connection pitch
      35 mm with spreaders
      27 mm without spreaders
      connections - terminals
      1 Everlink lug 2.5...95 mm² (rigid or stranded) conductor :copper
      1 Everlink lug 2.5...70 mm² (flexible) conductor :copper
      tightening torque
      5 N.m for 2.5...10 mm²
      9 N.m for 16...95 mm²
      local signalling
      Green flag for presence of auxiliary contacts
      number of slots
      1 slot(s) for auxiliary switch OF
      1 slot(s) for alarm switch SD
      1 slot(s) for voltage release MN or MX
      wire stripping length
      20 mm
      Environment
      quality labels
      CE
      standards
      EN/IEC 60947
      product certifications
      CCC
      EAC
      Marine
      colour
      Grey (RAL 7016)
      IP degree of protection
      IP40 (front cover) according to IEC 60529
      IK degree of protection
      IK07 according to IEC 62262
      pollution degree
      3 according to IEC 60947-1
      ambient air temperature for operation
      -25...70 °C
      ambient air temperature for storage
      -40...85 °C
      operating altitude
      5000 m with derating
      2000 m without derating
      mechanical durability
      20000 cycles according to IEC 947-1 Annex K ed 5.2 for In
      electrical durability
      10000 cycles according to IEC 947-1 Annex F ed 5.2 for In at 440 V
      height
      137 mm
      width
      81 mm
      depth
      80 mm
      product weight
      1.06 kg
      quantity per set
      Set of 1
      Offer Sustainability
      Sustainable offer status
      Green Premium product
      RoHS (date code: YYWW)
      Compliant  - since  1649  -  Schneider Electric declaration of conformity Schneider Electric declaration of conformity
      REACh
      Product environmental profile
      Product end of life instructions
      Need no specific recycling operations
    • Documents & Downloads

      Language
      • English
      User guide
      Date
      Size
      Add to My Documents
      Date 3/05/18
      Size 16.8 MB
      Date 13/02/18
      Size 9.9 MB
      Date 13/02/18
      Size 16.8 MB
      Date 13/02/18
      Size 9.9 MB
      Catalogue
      Date
      Size
      Add to My Documents
      Instruction sheet
      Date
      Size
      Add to My Documents
      CAD
      Date
      Size
      Add to My Documents
      Compact NSXm 16kA/70kA 16A/160A 3P EverLink circuit breaker
      Product environmental
      Date
      Size
      Add to My Documents
      Date 6/02/17
      Size 439 KB
    • Technical FAQs

      No results found.
      Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
    Nos conseillers sont disponibles pour répondre à vos questions de 8h00 à 18h00 du lundi au vendredi toute l'année.