Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

GV3ME63 Product picture
Discontinued

View all Schneider Legacy Products

Schneider Legacy Products - GV3ME63

Industry

GV3ME63 Product picture
Discontinued
View all Schneider Legacy Products
Schneider Legacy Products - GV3ME63
Industry

motor circuit breaker GV3-ME - 40..63 A - screw clamp terminal - thermomagnetic trip unit

Show more characteristics >
Add to My Products Remove from My Products

GV3ME63 is replaced by the following group of products:
Add Product Group to My Products Remove Product Group from My Products
  • Reason for substitution: End of life
  • Substitution date: 30 December 2008
Or GV3ME63 may be replaced by any of the following products:
Product
Qty
GV3P65
Qty
1
Add to My Products Remove from My Products
  • Reason for substitution: End of life
  • Substitution date: 30 December 2008
GV3P50
Qty
1
Add to My Products Remove from My Products
  • Reason for substitution: End of life
  • Substitution date: 30 December 2008
  • Main
    range
    TeSys
    product name
    TeSys GV3
    device short name
    Thermal magnetic circuit breaker
    product or component type
    Circuit breaker
    device application
    Motor
    poles description
    3P
    network type
    AC
    control type
    Push-button
    motor power kW
    22 kW at 400...415 V AC 50/60 Hz
    30 kW at 400...415 V AC 50/60 Hz
    30 kW at 500 V AC 50/60 Hz
    37 kW at 500 V AC 50/60 Hz
    37 kW at 660...690 V AC 50/60 Hz
    45 kW at 660...690 V AC 50/60 Hz
    trip unit technology
    Thermal-magnetic
    utilisation category
    AC-3 conforming to IEC 60947-4-1
    Category A conforming to IEC 60947-2
    connections - terminals
    Power circuit : screw clamp terminal 1 cable 2.5 mm² - cable stiffness: flexible - without cable end
    Power circuit : screw clamp terminal 1 cable 2.5...35 mm² - cable stiffness: solid
    Power circuit : screw clamp terminal 2 cable 16 mm² - cable stiffness: flexible - with cable end
    Complementary
    network frequency
    50/60 Hz
    mounting mode
    Fixed
    mounting support
    Plate
    Rail
    mounting position
    Horizontal
    Vertical
    thermal protection adjustment range
    40...63 A conforming to IEC 60947-4-1
    phase failure sensitivity
    Yes conforming to IEC 60947-4-1 § 7-2-1-5-2
    [Ue] rated operational voltage
    600 V AC 50/60 Hz conforming to CSA C22.2 No 14
    600 V AC 50/60 Hz conforming to UL 508
    690 V AC 50/60 Hz conforming to IEC 60947-2
    [Ui] rated insulation voltage
    690 V conforming to IEC 60947-2
    [Ith] conventional free air thermal current
    63 A conforming to IEC 60947-4-1
    network frequency
    50/60 Hz conforming to CSA
    50/60 Hz conforming to IEC 60947-4-1
    50/60 Hz conforming to UL
    [Uimp] rated impulse withstand voltage
    6 kV conforming to IEC 60947-2
    power dissipation per pole
    8 W
    mechanical durability
    30000 cycles
    electrical durability
    30000 cycles on AC-3 at 440 V In/2
    maximum number of switchings
    25 cyc/h
    rated duty
    Continuous conforming to IEC 60947-4-1
    tightening torque
    5 N.m - on EverLink BTR screw connectors - cable 2.5...3.5 mm²
    5 N.m - on EverLink BTR screw connectors - cable 2.5...16 mm²
    breaking capacity
    Icu 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
    Icu 100 kA at 230...240 V AC 50/60 Hz conforming to IEC 60947-2
    Icu 15 kA at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
    Icu 2 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2
    Icu 4 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
    [Ics] rated service short-circuit breaking capacity
    100 % at 230...240 V AC 50/60 Hz conforming to IEC 60947-2
    100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
    100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
    50 % at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
    60 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
    height
    120 mm
    width
    61 mm
    depth
    113 mm
    product weight
    0.7 kg
    Environment
    standards
    BS EN
    DIN EN 60947-2
    DIN EN 60947-4-1
    EN 60947-2
    EN 60947-4-1
    IEC 60947-2
    IEC 60947-4-1
    NF EN
    product certifications
    CSA
    LROS (Lloyds register of shipping)
    UL
    protective treatment
    TC
    IP degree of protection
    IP20 open mounted conforming to IEC 60529
    IP55 in enclosure conforming to IEC 60529
    shock resistance
    22 gn 20 ms conforming to IEC 60068-2-27
    vibration resistance
    2.5 gn 0...25 Hz conforming to IEC 60068-2-6
    ambient air temperature for operation
    -20...60 °C open mounted
    -20...40 °C in enclosure
    ambient air temperature for storage
    -40...80 °C
    fire resistance
    960 °C conforming to IEC 60695-2-1
    operating altitude
    <= 3000 m
    resistance to mechanical impact
    0.5 J
    Contractual warranty
    Warranty period
    18 months
  • Documents & Downloads

    Language
    • English
    Catalogue
    Date
    Size
    Add to My Documents
    TeSys GV - Catalogue 2017 - Motor circuit breakers
    Product environmental
    Date
    Size
    Add to My Documents
    Date 23/05/18
    Size 379.7 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Nos conseillers sont disponibles pour répondre à vos questions de 8h00 à 18h00 du lundi au vendredi toute l'année.