Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

A9XMEA08 Product picture
Discontinued

Range: iDPN Vigi

communication system

A9XMEA08

A9XMEA08 Product picture
Discontinued
Range: iDPN Vigi

communication system

A9XMEA08

Acti9 Smartlink - Modbus TCP/IP communication I/O module

Show more characteristics >
A9XMEA08  has not been replaced. Please contact your customer care centre for more information.
Add to My Products Remove from My Products

  • Main
    range of product
    Acti 9
    product name
    Acti 9 Smartlink
    product or component type
    Smart communication module
    device short name
    Smartlink SI B Ethernet
    Application type
    Breaker status monitoring
    Basic energy metering E
    Improved load monitoring E, U, I, P, Pf
    Load control
    Number max of connected devices
    Up to 7 wired devices
    group of channels
    1 group of 7 digital channels
    1 group of 1 analog channel
    supply current
    <= 1.5 A
    [Us] rated supply voltage
    24 V DC +/- 20 %
    connectivity to devices
    Analog input
    Digital input and output
    Pulse output meter
    Upstream connectivity
    Ethernet Modbus TCP/IP server
    Web server
    web server
    Embedded web page
    BMS controller compatible
    User interface
    Web page
    Complementary
    application specific I/O
    Pulse totalising counter
    Pulse converter
    protection type
    Overvoltage at 33 V DC for digital output
    Short-circuit protection for analogue input
    Against reverse polarity for auxiliary supply
    Against reverse polarity for input
    immunity to microbreaks
    10 ms
    reset
    Factory reset on front face
    input/output type
    2 inputs + 1 output per digital channel
    2 inputs per analog channel
    input type
    Voltage for analog input, 0...10 V DC
    Current for analog input, 4...20 mA
    Current sink for digital input, 24 V DC +/- 20 % at 2.5 mA
    maximum permanent current
    0.005 A for digital input
    absolute accuracy error
    +/- 1 % of full scale for analog input 12 bits
    electronic filtering time
    1 ms for digital input
    30 ms for analog input
    output type
    Logic current source 24 V DC 100 mA
    voltage drop
    <= 1 V digital output
    inrush current
    0.5 A for digital output
    3 A for power supply
    leakage current
    <= 0.1 mA for digital output
    local signalling
    1 LED yellow color for communication
    1 LED green, orange and red color for NS (Network Status)
    1 LED green and yellow color for communication (LK/ACT 10/100)
    1 LED green, orange and red color for status
    type of setting
    Modbus address 01...247 for address encoders
    mounting position
    Horizontal and vertical, on DIN rail with accessory
    colour
    White (RAL 9003)
    location of connection
    Front
    connections - terminals
    Plug-in connector qty: 1 for supply circuit
    Plug-in connector qty: 1 for communication bus
    Spring-loaded terminal Ti24 qty: 7 for digital input/output, ordered separately
    Plug-in connector qty: 1 for analog input
    RJ45 connector qty: 1 for ETHERNET, ordered separately
    clamping connection capacity
    1 x 0.5...1 x 1.5 mm², flexible with cable end for control
    1 x 0.5...1 x 1.5 mm², flexible without cable end for control
    1 x 0.5...1 x 1.5 mm², rigid with cable end for control
    1 x 0.5...1 x 1.5 mm², rigid without cable end for control
    2 x 0.2...2 x 1.5 mm², flexible with cable end for supply circuit
    2 x 0.2...2 x 1.5 mm², flexible without cable end for supply circuit
    2 x 0.2...2 x 1.5 mm², rigid with cable end for supply circuit
    2 x 0.2...2 x 1.5 mm², rigid without cable end for supply circuit
    2 x 0.25 mm² for twisted shielded pairs cable, flexible with cable end for communication bus
    2 x 0.25 mm² for twisted shielded pairs cable, flexible without cable end for communication bus
    2 x 0.25 mm² for twisted shielded pairs cable, rigid with cable end for communication bus
    2 x 0.25 mm² for twisted shielded pairs cable, rigid without cable end for communication bus
    2 x 0.25...2 x 1.5 mm² for twisted shielded pairs cable, rigid with cable end for analog input
    2 x 0.25...2 x 1.5 mm² for twisted shielded pairs cable, rigid without cable end for analog input
    2 x 0.25...2 x 1.5 mm² for twisted shielded pairs cable, flexible with cable end for analog input
    2 x 0.25...2 x 1.5 mm² for twisted shielded pairs cable, flexible without cable end for analog input
    wire stripping length
    7 mm for supply circuit
    7 mm for analog input
    10 mm for control
    7 mm for communication bus
    communication network type
    RS485 Modbus RTU, master at 9.6...19.2 kbauds with SUB-D 9 connector
    Ethernet Modbus TCP/IP, server at 10/100 Mbit/s with RJ45 connector
    9 mm pitches
    0 modules useful on Din rail
    height
    22.5 mm
    width
    359 mm
    depth
    42 mm
    product weight
    180 kg
    range compatibility
    Acti 9: Acti 9 iDPN
    Acti 9: Acti 9 iDPN Vigi
    Acti 9: Acti 9 DT40
    Acti 9: Acti 9 C40
    Acti 9: Acti 9 ITG40
    Multi 9: Multi 9 C60
    Acti 9: Acti 9 iID
    Acti 9: Acti 9 iSW-NA
    Acti 9: Acti 9 iC60
    Acti 9: Acti 9 DT60
    Acti 9: RCA iC60 Ti24 connector
    Linergy: Linergy FM
    Acti 9: Acti 9 iCT auxiliary
    Acti 9: Acti 9 I-NA
    Acti 9: Acti 9 Reflex iC60 Ti24 connector
    Acti 9: iTL auxiliary
    Acti 9: iOF+SD 24
    Acti 9: iACT24
    Acti 9: iATL24
    Powerlogic: pulse output meter
    Powerlogic: Modbus meter
    commissioning interface
    Web page
    Acti 9 Smart test
    Environment
    IP degree of protection
    IP20
    pollution degree
    3
    electromagnetic compatibility
    Resistance to electrostatic discharge 8 kV air discharge IEC 61000-4-2
    Resistance to electrostatic discharge 4 kV contact discharge IEC 61000-4-2
    Resistance to radiated electromagnetic fields 10 V/m 80 MHz...3 GHz IEC 61000-4-3
    Resistance to fast transient 2 kV 5...100 kHz power supply IEC 61000-4-4
    Resistance to fast transient 1 kV input/output IEC 61000-4-4
    Resistance to fast transient 1 kV communication bus IEC 61000-4-4
    Conducted EMC 10 V 0.15...80 MHz IEC 61000-4-6
    Immunity to magnetic fields at network frequency 30 A/m IEC 61000-4-8
    Radiated emission class A 30...1000 MHz IEC 61131-3 Ed.3
    Conducted emission class A 0.15...30 MHz IEC 61131-2
    vibration resistance
    1 gn /±3.5 mm, 5...300 Hz, 10 cycles conforming to IEC 60068-2-6
    shock resistance
    15 gn /11 ms
    fire resistance
    Other parts: 30 s at 650 °C conforming to IEC 60695-2-10
    On connection terminals: 30 s at 960 °C conforming to IEC 60695-2-10
    tropicalisation
    2
    relative humidity
    93 % at 40 °C
    operating altitude
    0...2000 m
    ambient air temperature for operation
    -25...60 °C
    ambient air temperature for storage
    -40...80 °C
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
    Available
  • Documents & Downloads

    Language
    • English
    User guide
    Date
    Size
    Add to My Documents
    Date 5/05/16
    Size 18.4 MB
    Date 30/03/18
    Size 9.6 MB
    Instruction sheet
    Date
    Size
    Add to My Documents
    CAD
    Date
    Size
    Add to My Documents
    Acti 9 Smartlink Ethernet - CAD model
    Smart Panels - typical architecture for small buildings
    Smart Panels - typical architecture for medium-size buildings
    Catalogue Page
    Date
    Size
    Add to My Documents
    Date 20/04/17
    Size 2.5 MB
    End of life manual
    Date
    Size
    Add to My Documents
    Date 22/05/14
    Size 113.5 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Nos conseillers sont disponibles pour répondre à vos questions de 8h00 à 18h00 du lundi au vendredi toute l'année.