Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

    140CPU65150C Product picture

    Range: Modicon Quantum

    Harsh environment

    140CPU65150C

    140CPU65150C Product picture
    Range: Modicon Quantum

    Harsh environment

    140CPU65150C

    Unity processor Modicon Quantum - 768 kB - 166 MHz - coated

    Show more characteristics >
    Add to My Favourites Remove from My Favourites

    • Main
      range of product
      Modicon Quantum automation platform
      product or component type
      Unity processor
      Complementary
      clock frequency
      166 MHz
      number of slots
      10
      16
      2
      4
      6
      number of racks
      2 - local rack(s)
      number of distributed I/O station
      63 station(s) - 1 rack(s) - 3 Modbus Plus network(s)
      number of remote I/O station
      31 - 2 S908 remote I/O rack(s)
      31 - 2 ethernet Quantum remote I/O rack(s)
      16 - 2 ethernet X80 remote I/O rack(s)
      discrete I/O number
      Unlimited (31 drops of 28 slots max) - ethernet remote I/O
      8000 inputs, 8000 outputs - distributed - per network Modbus Plus
      Unlimited (26 slots max) - local
      31744 inputs, 31744 outputs - remote
      analogue I/O number
      Unlimited (26 slots max) - local
      1984 inputs,1984 outputs - S908 remote I/O
      Unlimited (31 drops of 28 slots max) - ethernet remote I/O
      500 inputs, 500 outputs - distributed - per network Modbus Plus
      application specific I/O
      Accurate time stamping
      Counter
      High-speed interrupt inputs
      Serial link
      communication service
      Ethernet router
      number of optional modules
      6 ( Ethernet, Modbus, Modbus Plus, Profibus DP, Sy/Max)
      maximum number of connections
      1 ( USB)
      2 ( AS-Interface) - distributed
      4 ( AS-Interface) - remote
      6 ( Ethernet TCP/IP) - local
      6 ( Modbus Plus) - local
      6 ( Profibus DP) - local
      1 ( Modbus) - RS232/485 Modbus/ASCII
      integrated connection type
      1 Modbus Plus with
      1 Ethernet TCP/IP with
      1 Modbus with
      1 USB with
      checks
      Process control
      memory description
      Expandable 7168 kB - program with PCMCIA card
      Expandable 8 MB - file storage with PCMCIA card
      Internal RAM 768 kB
      switch function
      Key switch memory port on/off
      application structure
      1 cyclic/periodic master task -
      1 periodic fast task -
      128 I/O interrupt tasks -
      128 interrupt tasks -
      32 timer interrupt tasks -
      4 auxiliary tasks -
      number of instructions per ms
      10.28 Kinst/ms if 100 % Boolean
      10.07 Kinst/ms if 65 % Boolean and 35 % numerical
      system overhead
      1 ms - master task
      0.2 ms - fast task
      bus current requirement
      2160 mA
      local signalling
      1 LED green for Ethernet activity (COM)
      1 LED red for Ethernet collision
      electrical connection
      1 connector, connector type: RJ45 for connecting Ethernet network
      1 connector, connector type: RJ45 for connecting Modbus bus
      1 female connector, connector type: SUB-D 9 for connecting to the Modbus Plus network
      Environment
      protective treatment
      Conformal coating Humiseal 1A33
      product certifications
      CE
      CSA
      GOST
      UL
      ATEX zone 2
      IEC-Ex
      Misc (Marine)
      standards
      HazLoc
      Offer Sustainability
      Sustainable offer status
      Green Premium product
      RoHS (date code: YYWW)
      Compliant  - since  1009  -  Schneider Electric declaration of conformity Schneider Electric declaration of conformity
      REACh
      Product environmental profile
      Product end of life instructions
      Available
      Contractual warranty
      Warranty period
      18 months
    • Documents & Downloads

      Language
      • English
      Catalogue
      Date
      Size
      Add to My Documents
      Firmware - Updates
      Date
      Size
      Add to My Documents
      Date 2/06/17
      Size 554.3 KB
      Instruction sheet
      Date
      Size
      Add to My Documents
      Date 14/12/17
      Size 825.6 KB
      Certificate
      Date
      Size
      Add to My Documents
      Date 19/06/18
      Size 363.5 KB
      ATEX-IECEx
      Date 19/06/18
      Size 2.2 MB
      Date 19/06/18
      Size 100.6 KB
      Date 19/06/18
      Size 1.5 MB
      UL_E486184_NRAQ-NRAQ7_ALL_JAN2018
      Date 19/06/18
      Size 160.6 KB
      Date 19/06/18
      Size 173.2 KB
      Declaration of conformity
      Date
      Size
      Add to My Documents
      Date 19/06/18
      Size 233.5 KB
      Date 19/06/18
      Size 510.4 KB
      End of life manual
      Date
      Size
      Add to My Documents
    • Technical FAQs

      No results found.
      Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
    Nos conseillers sont disponibles pour répondre à vos questions de 8h00 à 18h00 du lundi au vendredi toute l'année.