Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

140AVO02000 Product picture

Range: Modicon Quantum

Standard environment

140AVO02000

140AVO02000 Product picture
Range: Modicon Quantum

Standard environment

140AVO02000

analog output module Modicon Quantum - 4 O

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    Modicon Quantum automation platform
    product or component type
    Analogue output module
    Complementary
    analogue output number
    4
    addressing requirement
    4 output words
    analogue output range
    +/- 10 V >= 1000 Ohm bipolar voltage
    +/- 5 V >= 500 Ohm bipolar voltage
    0...10 V >= 1000 Ohm unipolar voltage
    0...5 V >= 500 Ohm unipolar voltage
    analogue output resolution
    12 bits
    analogue output current
    -10...10 mA
    source resistance
    0.1 Ohm
    cable distance between devices
    400 m
    absolute accuracy error
    +/- 0.15 % of full scale at 25 °C
    linearity
    +/- 1 LSB
    accuracy drift according to temperature
    0.003 % of full scale/°C unipolar
    0.004 % of full scale/°C bipolar
    0.005 % of full scale/°C maximum unipolar
    0.007 % of full scale/°C maximum bipolar
    isolation between channels
    500 V for 1 minute 47...63 Hz AC
    isolation between channels and bus
    780 V for 1 minute AC
    update time
    3 ms
    setting time
    700 µs to +/- 0.1 % of the final value maximum
    bus current requirement
    700 mA
    power dissipation in W
    <= 4.5 W
    associated fuse rating
    0.063 mA 3 AG fast blow 250 V
    marking
    CE
    local signalling
    4 LEDs green channel is turned on
    4 LEDs red channel fault
    1 LED green bus communication is present (Active)
    1 LED red external fault
    module format
    Standard
    product weight
    0.3 kg
    Environment
    product certifications
    CUL
    FM Class 1 Division 2
    standards
    CSA C22.2 No 142
    UL 508
    resistance to electromagnetic fields
    10 V/m 80...2000 MHz conforming to IEC 801-3
    ambient air temperature for operation
    0...60 °C
    ambient air temperature for storage
    -40...85 °C
    relative humidity
    95 % without condensation
    operating altitude
    <= 5000 m
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
    Available
    Contractual warranty
    Warranty period
    18 months
  • Documents & Downloads

    Language
    • English
    User guide
    Date
    Size
    Add to My Documents
    Catalogue
    Date
    Size
    Add to My Documents
    CAD
    Date
    Size
    Add to My Documents
    Analog I/O module
    Date 25/04/17
    Size 9.4 KB
    Date 25/04/17
    Size 143.5 KB
    Date 25/04/17
    Size 445.1 KB
    Date 25/04/17
    Size 28 KB
    Certificate
    Date
    Size
    Add to My Documents
    Date 6/08/18
    Size 233.4 KB
    Date 19/06/18
    Size 363.5 KB
    Declaration of conformity
    Date
    Size
    Add to My Documents
    Date 19/06/18
    Size 233.5 KB
    Date 6/08/18
    Size 510.4 KB
    End of life manual
    Date
    Size
    Add to My Documents
    Marine certificate
    Date
    Size
    Add to My Documents
    Date 23/05/18
    Size 78.9 KB
    Date 13/02/18
    Size 2.3 MB
    Date 16/01/18
    Size 173.6 KB
    Date 16/01/18
    Size 2.6 MB
    LR_04.00057E1_QUANTUM_MAY2016
    Date 16/01/18
    Size 504.7 KB
    Date 16/01/18
    Size 68 KB
    Date 16/01/18
    Size 6.6 MB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Racks for Modules Mounting
    Dimensions of Modules and Racks


    (1)
    2 slots
    (2)
    3 slots
    (3)
    4 slots
    (4)
    6 slots
    (5)
    10 slots
    (6)
    16 slots


  • Connections and Schema

    Analog Output 4-Channel Voltage Module
    Wiring Diagram


    N/C
    Not Connected

    External Wiring Recommendation

    1. Master override is an input connected via an internal relay contact to the output when the module is not active. If connected to an external source, the master override input must be fused by a 1/16 A fuse.

    2. If the master override is not connected to an external source, then it must be connected to common of that channel.The master override relay transition time is typically 2 ms.

    3. The master override inputs must be from an external supply with a source impedance of <200 Ω or tied to system common. These inputs for channels that are in use should not be allowed to float and may be unique for each.