    • Main
      range of product
      Modicon Quantum automation platform
      product or component type
      Intrinsically safe analog output module
      software designation
      ProWORX
      Unity Pro
      Concept V2.2 and above
      Complementary
      product destination
      In conjunction with products for zone 20, 21 or 22
      analogue output number
      8
      analogue output range
      0...20 mA 0 to 20000 points
      0...25 mA 0 to 25000 points
      4...20 mA 15 bits, 0 to 16000 points
      4...20 mA 15 bits, 0 to 4095 points
      loop resistance
      <= 500 Ohm
      absolute accuracy error
      +/- 0.2 % of full scale at 25 °C
      accuracy drift according to temperature
      40 ppm/°C
      <= 70 ppm/°C
      linearity
      +/- 1 LSB
      update time
      4 ms
      setting time
      1 ms to +/- 0.1 % of the final value
      isolation between channels and bus
      1780 Vrms for 60 s AC
      fault type
      Open circuit 4...20 mA
      power dissipation in W
      12.5 W
      hot swapping fallback
      Not allowed per intrinsic safety standards
      protection type
      Internal fuse
      marking
      II1 G/D-EEx ia IIC
      CE
      bus current requirement
      2.5 A
      module format
      Standard
      product weight
      0.3 kg
      Environment
      standards
      Directive ATEX 94/9/EC
      EN 50014
      EN 50284
      UL 508
      EN 50020
      EN 50039
      EN 50281-1-1
      CSA C22.2 No 142
      dust zone
      Outside zone
      product certifications
      Hazardous location class 1, division 1 groups A, B, C
      C-Tick.1
      SIRA 02ATEX2345X
      FM Class 1 Division 2
      resistance to electrostatic discharge
      4 kV contact conforming to IEC 801-2
      8 kV on air conforming to IEC 801-2
      resistance to electromagnetic fields
      10 V/m 80...2000 MHz conforming to IEC 801-3
      ambient air temperature for operation
      0...60 °C
      ambient air temperature for storage
      -40...85 °C
      relative humidity
      95 % without condensation
      operating altitude
      <= 5000 m
      Contractual warranty
      Warranty period
      18 months
    • Documents & Downloads

      Language
      • English
      User guide
      Date
      Size
      Add to My Documents
      End of life manual
      Date
      Size
      Add to My Documents
    • Technical FAQs

      No results found.
      Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
    Nos conseillers sont disponibles pour répondre à vos questions de 8h00 à 18h00 du lundi au vendredi toute l'année.