    • Main
      range of product
      Modicon Quantum automation platform
      product or component type
      Intrinsically safe temperature input module
      software designation
      Concept V2.2 and above
      Unity Pro
      type of filter
      Plus notch input filter 50/60 Hz thermocouple
      Single low pass input filter 20 Hz thermocouple
      Complementary
      product destination
      In conjunction with products for zone 20, 21 or 22
      analogue input number
      8
      analogue input type
      Low level voltage -100...100 mV
      Low level voltage -25...25 mV
      Thermocouple - 210...760 °C thermocouple J
      Thermocouple - 270...1000 °C thermocouple E
      Thermocouple - 270...1370 °C thermocouple K
      Thermocouple - 270...400 °C thermocouple T
      Thermocouple - 50...1665 °C thermocouple R
      Thermocouple - 50...1665 °C thermocouple S
      Temperature probe - 200...850 °C Pt 100, Pt 200, Pt 500, Pt 1000
      Temperature probe - 60...180 °C Ni 100, Ni 200, Ni 500, Ni 1000
      Thermocouple - 130...1820 ° C thermocouple B
      measurement current
      0.5 mA Pt 500, Pt 1000, Ni 500, Ni 1000
      2.5 mA Pt 100, Pt 200, Ni 100, Ni 200
      source resistance
      < 200 Ohm thermocouple
      input impedance
      > 1 MOhm thermocouple
      > 10 MOhm RTD
      common mode rejection
      > 100 dB 50/60 Hz RTD
      > 120 dB 50/60 Hz thermocouple
      cold junction compensation
      Internal 0...60 °C thermocouple
      linearity
      0.003 % of full scale RTD
      resolution
      0.76 µV (16 bits) -25...25 mV millivolt
      1 °C, 0.1 °C, 1 °F, 0.1 °F thermocouple
      12 bits + sign (0.1 °C) RTD
      3.05 µV (16 bits) -100...100 mV millivolt
      measurement accuracy
      +/- 2 °C + 0.1 % of reading thermocouple E
      +/- 2 °C + 0.1 % of reading thermocouple J
      +/- 2 °C + 0.1 % of reading thermocouple K
      +/- 2 °C + 0.1 % of reading thermocouple T
      +/- 4 °C + 0.1 % of reading thermocouple B
      +/- 4 °C + 0.1 % of reading thermocouple R
      +/- 4 °C + 0.1 % of reading thermocouple S
      +/- 0.5 °C RTD at 25 °C
      20 µV + 0.1 % of reading millivolt at 25 °C
      +/- 0.9 °C RTD at 0...60 °C
      absolute accuracy error
      +/- 0.05 % of full scale RTD at 25 °C
      +/- 0.1 % of full scale maximum RTD at 25 °C
      accuracy drift according to temperature
      0.15 mV/°C + 0.0015 % of reading/°C max thermocouple
      update time
      1 s TC/millivolt thermocouple
      1.35 s 3 wires RTD
      750 ms 2 or 4 wires RTD
      isolation between channels and bus
      2500 V DC for 1 minute
      1780 V 47...63 Hz AC for 1 minute
      fault type
      Out of range
      Broken wire
      power dissipation in W
      2 W
      hot swapping fallback
      Not allowed per intrinsic safety standards
      protection type
      Internal fuse
      marking
      CE
      II1 G/D-EEx ia IIC
      bus current requirement
      400 mA
      module format
      Standard
      product weight
      0.3 kg
      Environment
      standards
      EN 50020
      EN 50284
      Directive ATEX 94/9/EC
      EN 50039
      EN 50014
      CSA C22.2 No 142
      EN 50281-1-1
      dust zone
      Outside zone
      product certifications
      SIRA 02ATEX2345X
      FM Class 1 Division 2
      C-Tick.1
      Hazardous location class 1, division 1 groups A, B, C
      resistance to electrostatic discharge
      4 kV contact conforming to IEC 801-2
      8 kV on air conforming to IEC 801-2
      resistance to electromagnetic fields
      10 V/m 80...2000 Hz conforming to IEC 801-3
      ambient air temperature for operation
      0...60 °C
      ambient air temperature for storage
      -40...85 °C
      relative humidity
      95 % without condensation
      operating altitude
      <= 5000 m
      Contractual warranty
      Warranty period
      18 months
    • Documents & Downloads

      Language
      • English
      User guide
      Date
      Size
      Add to My Documents
      End of life manual
      Date
      Size
      Add to My Documents
    • Technical FAQs

      No results found.
      Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
    • Dimensions Drawings

      Racks for Modules Mounting
      Dimensions of Modules and Racks


      (1)
      2 slots
      (2)
      3 slots
      (3)
      4 slots
      (4)
      6 slots
      (5)
      10 slots
      (6)
      16 slots


    • Connections and Schema

      Intrinsically Safe Analog Input Module
      Cenelec Certified Wiring Diagrams

      Module configured with an RTD/Resistance connection:


      Module configured with a Thermocouple connection: