    AccuSine SWP

    LV active harmonic conditioner

    -

    AccuSine SWP
    • Features

      Global compensation or individual harmonic compensation, from H3 to H50 (selectable),

      • correction of the displacement power factor, cosinus (adjustable),
      • configuration for types of load: computer loads, rectifier, etc.,
      • IGBT technology and control by DSP circuit,
      • 3 LEDs to indicate operating condition,
      • digital 7-language display unit,
      • configuration and parameter assignment menu,
      • remote control (lockable),
      • redundancy parallel connection facility,
      • wide range of current transformers, etc.

      Technical Data
      System input

      • Nominal voltage: 400 V - 20 + 15%
      • Nominal frequency: 50Hz, 60 Hz, +/-8%
      • Number of phases: 3 phases with or without neutral

      Technical characteristics

      • Compensated harmonic currents: H3 to 50, full compensation or individual compensation.
      • Harmonic attenuation rate: THDI load /THDI system less than 10, at the nominal rating of the compensator.
      • Correction of cos.: lagging or leading, up to 1.0 Response time< 40 ms,
      • Overload: possibility of continuous operation with current limitation.

      Environmental Conditions

      • Operating temperature: 0 to 30°C continuous, <25°C recommended
      • Relative humidity: 0 to 95 % without condensation
      • Operating altitude: < 1000 m

      Reference technical standards: IEC/EN



      Benefits

      • SineWave is extremely compact. It can be wall-mounted or installed in a switchgear cubicle;
      • SineWave can be connected in parallel, allowing future increases in power demand without disconnecting the supply;
      • SineWave adapts automatically to any single-phase or three-phase load: computer load, variable speed drives, etc. It is compatible with any type of neutral systems.

      Applications

      By neutralising harmonics SineWave eliminates:

      • nuisance tripping of circuit-breakers,
      • Premature ageing of equipment.

      By correcting the cos., SineWave allows:

      • energy savings,
      • Full compatibility of generator sets with capacitive loads
    Nos conseillers sont disponibles pour répondre à vos questions de 8h00 à 18h00 du lundi au vendredi toute l'année.