Can the 752/CD2RC do pulse output?

From the installation brochure

Output 1 (for lighting loads, connected to terminals L’ and N)
This output operates in exactly the same way as the output in the single-load
sensor unit and switches the connected load when:
• Motion is detected by the user-selected combination of PIR and Ultrasonic
sensors.
• The ambient light level is below the set light level adjustment.
Output 1 uses TIME 1 adjustment to set the switch-off time delay. The time
adjustment can be set for delays from 5sec to 30min. The 1sec Pulse and Test
settings are used during setup
. Refer to Setup and Operation.

Only if left in test mode

http://updates.clipsal.com/ClipsalOnline/Files/Brochures/W0001639.pdf